## Air Conditioning for Every Room

Multi-split systems connect two to five indoor units to a single outdoor unit. Single split systems cover individual rooms, a light commercial range serves shops, offices and classrooms, and VRF handles whole buildings.
**2 – 5**
indoor units per multi-split outdoor unit
**4.5 – 12 kW**
multi-split outdoor units, 14,000 – 42,000 Btu/h
**−22 °C**
heating operation down to −22 °C outside
**R32**
refrigerant across the split range
Four ranges

### Choose a system

Start with the size of the job: one room, several rooms, one large space, or a whole building.
- Multi Split One outdoor unit serves two to five rooms, with wall, cassette, console and ducted indoor units mixed on one system. 8 units 4.5 – 12 kW View range
- Single Split Matched CA-Smart and CM-Smart Premium Voice indoor and outdoor units for a single room, office or small shop. 7 systems 2.75 – 7.2 kW View range
- Light Commercial R32 outdoor units from 12,000 to 60,000 Btu/h with cassette, ducted, ceiling-floor and console indoor units. 12 units 3.5 – 17.6 kW View range
- VRF Mini VRF, modular Mini VRF and the ARV7 full DC inverter platform, with every room controlled on its own. 3 families to 144 HP View range

#### No installation needed

- Portable air conditioners No installation: wheel it in and fit the window kit. 7,000 to 14,000 Btu/h.
- Dehumidifiers The T Series removes 20, 30 or 50 litres of moisture a day.
Compare

### Which system fits the job

| System | Best for | Capacity | Indoor units |
| --- | --- | --- | --- |
| Multi split | Two to five rooms from one outdoor unit | 4.5 – 12.0 kW | 2 – 5 per outdoor unit |
| Single split | One room, office or small shop | 2.75 – 7.2 kW | 1 wall unit per outdoor unit |
| Light commercial | Shops, restaurants, classrooms, surgeries and open-plan offices | 12,000 – 60,000 Btu/h | 1 cassette, duct, ceiling-floor or console unit per outdoor unit |
| Mini VRF | Homes, shops and small offices | 8.0 – 18.0 kW cooling | Many, each room controlled on its own |
| ARV7 modular VRF | Offices, hotels, schools, healthcare and retail | 25.2 – 101 kW per module, systems to 144 HP | Up to 61 on a single 36 HP module |

Shared features

### What every system shares

- Wide operating window Cooling from −15 °C to 52 °C and heating from −22 °C to 24 °C outside, so the same system heats in winter and cools in summer.
- Intelligent defrost Defrost runs only when the coil needs it rather than on a fixed cycle, improving efficiency by around 5% and heating efficiency by up to 20% at low outdoor temperatures.
- All-DC inverter platform DC inverter compressors and fan motors with advanced control logic, and a protective multi-layer coating on the outdoor casing.
- Independently rated C-Series indoor units are tested to EN 14825:2018, with A++ / A+ energy classes across the CA and CC ranges.
Documents

### Catalogue and brochures

- AUX UK Product Catalogue The full AUX UK range: heat pumps, air conditioning and fan coil units. PDF · 19 MB
- Need another document? Brochures, manuals and installation guides are available from our technical team. Contact us
FAQs

### Frequently asked questions

Quick answers to help you choose between the AUX air conditioning ranges.

#### Choosing a system

**What is the difference between single split, multi split and VRF?**
A single split pairs one indoor unit with its own outdoor unit, for one room. A multi split connects two to five indoor units to one outdoor unit. VRF serves many indoor units from one outdoor unit, or a bank of modular outdoor units, on a single refrigerant circuit, with every room controlled on its own. Light commercial systems pair one larger indoor unit with an outdoor unit for shops, offices and classrooms.
**Which AUX air conditioning system do I need?**
Start with the size of the job: one room (single split), several rooms (multi split), one large space (light commercial) or a whole building (VRF). Where no installation is possible, portable air conditioners just plug in. Send us the room list and loads and our technical team will size the system.
**Can AUX air conditioning heat as well as cool?**
Yes. The same system heats in winter and cools in summer: cooling works from −15 °C to 52 °C outside and heating from −22 °C to 24 °C. Defrost runs only when the coil needs it, which improves heating efficiency at low outdoor temperatures.

#### Refrigerant and warranty

**Which refrigerant does AUX air conditioning use?**
The split range – single split, multi split and light commercial – uses R32. Portable air conditioners and dehumidifiers use the natural refrigerant R290. Mini VRF comes in R410A and R32 versions.
**Who should install and service my air conditioning?**
A qualified, certified professional, who commissions the system and signs a commissioning record. After that, air conditioning is serviced every year by an F-Gas certified engineer.
**Do AUX air conditioners have a warranty?**
Yes. AUX air conditioners supplied by AUX UK and installed in UK homes have a 10-year product warranty from the date of commissioning. To keep the full term, register the system within 90 days of commissioning and have it serviced every year by an F-Gas certified engineer. The steps are on the warranty page.

### Not sure which system you need?

Send us the room list and loads and our technical team will size the system and confirm the indoor unit combination.

---

AUX UK (Alp Heating Ltd) · 9–10 Helix Business Park, Camberley, Surrey, GU15 2QT, United Kingdom · +44 345 257 7387 · info@auxuk.com · https://auxuk.com