# AUX R290 Monobloc Air Source Heat Pumps UK | AUXUK

> AUX R290 monobloc heat pumps from 4 kW to 40 kW: A+++ at 35 °C and 55 °C, 80 °C flow, MCS certified and Boiler Upgrade Scheme ready. Specs and manuals.

URL: https://auxuk.com/aux-r290-monoblock
Last updated: 2026-10-27

## R290 Monobloc Heat Pumps

Propane monoblocs from 4 kW to 16 kW for homes and 22 kW to 40 kW for commercial buildings. The sealed refrigerant circuit stays inside the outdoor unit, so the installer makes water-side connections only.
**A+++**
energy class at both 35 °C and 55 °C flow
**80 °C**
maximum flow temperature, held down to −10 °C outside
**GWP 3**
R290 natural refrigerant
**128 kW**
cascade of up to 8 units on one system
Why R290 monobloc

### Built for UK radiators, underfloor heating and fan coils

- Full output in cold weather Rated heating output is maintained at −7 °C outside, and the unit keeps supplying 80 °C water down to −10 °C.
- MCS certified and grant ready Every domestic model is MCS certified and listed in the Product Characteristics Database at 35 °C and 55 °C. Installations qualify for the Boiler Upgrade Scheme through an MCS-certified installer.
- Open controls Native RS485 Modbus with a documented register map, so Passiv UK and Adia Thermal controls connect without an adapter.
- Built for installers Built-in strainer, 3 kW back-up heater on single-phase models (9 kW on three-phase), weather compensation as standard and a dual-zone option.
Features

### What sets the R290 monobloc apart

- Stylish design AUX AI Thermal Monobloc system is characterized by its stylish matte black casing made from weather resistant materials, ensuring its aesthetic appeal remains for years to come.
- Energy efficiency A+++ The R290 AI Thermal boasts energy efficiency of A+++/A+++. Its SCOP is 5.4*
- Hot water to 80 °C The AUX R290 Monobloc System provides hot water reaching a temperature up to 80 °C.
- Stylish intuitive control 27 language menu, stylish casing, heat pump can be set up via USB and the controller for easy commissioning.
- Low level noise AUX heat pumps feature inverter compressors for quiet outdoor operation. With triple insulation and AUX patented fan design noise levels are reduced to 35 dB(A) at 3 m. The silent mode function offers two levels for added comfort.
- Flexible design solutions Flexible compatibility with various heating systems including: underfloor, radiators or fan coil units. Option also to power from your solar system.
- Dual temperature zone Catering to individual preferences, this feature offers distinct climate control for different areas, ensuring personalised comfort in homes or workplaces.
- Smart Grid ready Heat pumps marked with SG Ready label are equipped with control system that allows to connect a single heat pump into a smart grid.
Domestic range

### 4 kW to 16 kW, single and three phase

Seven single-phase outputs from 4 kW to 16 kW and five three-phase outputs from 8 kW to 16 kW. All models are A+++ at 35 °C and 55 °C flow, MCS certified and PCDB registered.

#### Single phase · 220 – 240 V · 3 kW back-up heater

| SKU | Model | Output | Unit size W × D × H | R290 charge | PCDB index 35 °C / 55 °C |
| --- | --- | --- | --- | --- | --- |
| A1010 | ACHP-H04/4R2HA-M | 4 kW | 1130 × 420 × 710 mm | 0.55 kg | 110434 / 110432 |
| A1011 | ACHP-H06/4R2HA-M | 6 kW | 1130 × 420 × 710 mm | 0.55 kg | 110442 / 110440 |
| A1012 | ACHP-H08/4R2HA-M | 8 kW | 1280 × 420 × 1040 mm | 0.85 kg | 110450 / 110448 |
| A1013 | ACHP-H10/4R2HA-M | 10 kW | 1280 × 420 × 1040 mm | 0.85 kg | 110458 / 110456 |
| A1014 | ACHP-H12/4R2HA-M | 12 kW | 1280 × 420 × 1040 mm | 1.35 kg | 110466 / 110464 |
| A1015 | ACHP-H14/4R2HA-M | 14 kW | 1280 × 420 × 1040 mm | 1.35 kg | 110474 / 110472 |
| A1016 | ACHP-H16/4R2HA-M | 16 kW | 1280 × 420 × 1040 mm | 1.35 kg | 110482 / 110480 |

#### Three phase · 380 – 415 V · 9 kW back-up heater

| SKU | Model | Output | Unit size W × D × H | R290 charge |
| --- | --- | --- | --- | --- |
| A1022 | ACHP-H08/5R2HA-M | 8 kW | 1280 × 420 × 1040 mm | 0.85 kg |
| A1023 | ACHP-H10/5R2HA-M | 10 kW | 1280 × 420 × 1040 mm | 0.85 kg |
| A1024 | ACHP-H12/5R2HA-M | 12 kW | 1280 × 420 × 1040 mm | 1.35 kg |
| A1025 | ACHP-H14/5R2HA-M | 14 kW | 1280 × 420 × 1040 mm | 1.35 kg |
| A1026 | ACHP-H16/5R2HA-M | 16 kW | 1280 × 420 × 1040 mm | 1.35 kg |

Order by SKU and quote the model reference for technical or warranty enquiries.
System design

### Design figures for the installer

#### Design flow temperatures

**Underfloor heating**
30 – 35 °C
**Fan coil units**
30 – 45 °C
**Radiators**
40 – 50 °C
**HW cylinder**
50 – 55 °C
**Cooling, fan coil units**
7 – 18 °C
**Cooling, floor**
18 – 25 °C

#### Recommended HW cylinder volume

**4 – 6 kW**
100 – 250 litres
**8 – 10 kW**
150 – 300 litres
**12 – 16 kW**
200 – 500 litres

#### Supplied with every unit

**Controller**
Wired, with app control available
**Strainer**
Built in
**Expansion vessel**
5 litres, 1.0 bar pre-charge
**Weather compensation**
Standard
**Anti-freeze protection**
Standard
**Dual-zone control**
Option
Commercial range

### 22 kW to 40 kW three-phase monobloc

A twin-fan monobloc for commercial buildings, multi-dwelling schemes, schools and larger off-gas properties. Up to eight units can be cascaded, giving a combined output of up to 320 kW with 40 kW units.
AUX R290 commercial monobloc, twin-fan outdoor unit

#### Three phase · 380 – 415 V · 9 kW back-up heater · wired colour controller

| SKU | Model | Output | Energy class 35 / 55 °C |
| --- | --- | --- | --- |
| A1027 | ACHM-H22/5R2A | 22 kW | A+++ / A+++ |
| A1028 | ACHM-H26/5R2A | 26 kW | A+++ / A+++ |
| A1029 | ACHM-H30/5R2A | 30 kW | A+++ / A+++ |
| A1030 | ACHM-H35/5R2A | 35 kW | A+++ / A+++ |
| A1031 | ACHM-H40/5R2A | 40 kW | A+++ / A+++ |

#### Cascade and buffer

**Units in cascade**
Up to 8
**Buffer**
Common buffer tank
**Sensor**
Single buffer sensor

#### Operating range · outlet water

**Heating**
+30 to +85 °C
**Domestic hot water**
+30 to +75 °C
**Cooling**
+5 to +25 °C

#### Operating range · outside air

**Heating**
−30 to +43 °C
**Domestic hot water**
−30 to +43 °C
**Cooling**
−15 to +48 °C
Controls and integrations

### Connects to the controls you already use

- Native Modbus RS485 Modbus with a documented register map, so third-party controls and building management systems connect directly, without a gateway or adapter.
- Passiv UK The AUX R290 monobloc is a supported model on Passiv smart heat pump control, with its own installation guide and commissioning notes.
- Adia Thermal A pre-plumbed hydraulic hub with room-by-room load compensation and a built-in heat meter, connected to the heat pump over Modbus.
Documents

### Manuals and data sheets

- AUX R290 Heat Pump Brochure PDF · 7.1 MB
- AUX UK Product Catalogue PDF · 19 MB
- R290 Heat Pump Installation and Commissioning Manual PDF · 8.7 MB
- R290 Heat Pump Installation and Operation Manual PDF · 24 MB
- R290 Heat Pump Technical Data Manual PDF · 19 MB
- R290 Heat Pump Technical and Service Manual PDF · 5.5 MB
- R290 Heat Pump Maintenance Manual PDF · 6.7 MB
- R290 Heat Pump Parameter Description Manual PDF · 924 KB
- R290 Heat Pump Unit Operating Parameter Manual PDF · 5.3 MB
- R290 Heat Pump Electrical Requirements PDF · 334 KB
- R290 Heat Pump Schematics PDF · 550 KB
- XK08 Wired Controller Manual PDF · 15 MB
- R290 Heat Pump Certificate PDF · 1.7 MB
- Need another document? Our technical team can help with sizing, wiring and commissioning questions. Contact us
FAQs

### Frequently asked questions

Quick answers about the AUX R290 monobloc heat pump for homeowners and installers.

#### The R290 monobloc

**What sizes does the AUX R290 monobloc heat pump come in?**
Domestic models run from 4 kW to 16 kW: seven single-phase outputs from 4 kW to 16 kW and five three-phase outputs from 8 kW to 16 kW. For commercial buildings there is a twin-fan, three-phase monobloc from 22 kW to 40 kW, and up to eight units can be cascaded on one system. The SKUs are in the domestic range and commercial range tables.
**Can the R290 heat pump work with radiators?**
Yes. It is built for UK radiators, underfloor heating and fan coil units, and supplies water up to 80 °C, held down to −10 °C outside. Typical design flow temperatures are 40 – 50 °C for radiators, 30 – 35 °C for underfloor heating and 30 – 45 °C for fan coil units.
**Does the AUX R290 heat pump qualify for the Boiler Upgrade Scheme?**
Yes. Every domestic model is MCS certified and listed in the Product Characteristics Database at 35 °C and 55 °C, so installations by an MCS-certified installer qualify for the Boiler Upgrade Scheme grant of up to £7,500. Who is eligible and how the grant works is explained on the homeowner page.
**Why does it use R290 refrigerant?**
R290 is a natural refrigerant with a global warming potential of 3. In a monobloc the sealed refrigerant circuit stays inside the outdoor unit, so the installer makes water-side connections only.

#### Installation and support

**How loud is the R290 outdoor unit?**
Inverter compressors, triple insulation and the AUX patented fan design bring noise down to 35 dB(A) at 3 m. A silent mode adds two quieter levels.
**Which heating controls can it connect to?**
The unit has native RS485 Modbus with a documented register map, so Passiv UK and Adia Thermal controls, and building management systems, connect without an adapter. A wired controller is supplied with every unit, and app control is available.
**Is there a warranty on AUX heat pumps?**
Yes. AUX heat pumps supplied by AUX UK and installed in UK homes have a 10-year product warranty from the date of commissioning. To keep the full term, register within 90 days of commissioning and have the heat pump serviced every year by an MCS-certified company. The steps are on the warranty page.

### 10-year product warranty

Every AUX heat pump supplied by AUX UK is covered from the date of commissioning and supported by our own technical team in the UK.

---

AUX UK (Alp Heating Ltd) · 9–10 Helix Business Park, Camberley, Surrey, GU15 2QT, United Kingdom · +44 345 257 7387 · info@auxuk.com · https://auxuk.com
