# AUX Fan Coil Units for Heat Pump Systems UK | AUXUK

> AUX fan coil units for heat pumps: heating and cooling from one water circuit, in wall-mounted, 4-way cassette, 130 mm slim floor and concealed ducted models.

URL: https://auxuk.com/fan-coil-units
Last updated: 2026-10-27

## Fan Coil Units for Heat Pump Systems

Heating and cooling from a single water circuit, and a natural partner for a heat pump where a low flow temperature would leave radiators undersized.
**130 mm**
slimline floor-standing depth
**50 °C**
rated heating water temperature on the slim range
**4 families**
floor, wall, cassette and concealed
**18.9 kW**
largest cassette heating output
How it works

### One water circuit, a fan coil in each room

- Floor-standing slim 130 mm deep
- Wall-mounted Q Series 3.50 – 8.16 kW heating
- Cassette 4.80 – 18.90 kW heating
- Concealed M Series 2.70 – 18.90 kW heating
Four families

### Pick the unit by where it goes in the room

- Floor-standing slim 4 models · 130 mm deep
- Wall-mounted Q Series 5 models
- Cassette 8 models
- Concealed M Series 9 models

#### Floor-standing slim

A 130 mm deep exposed cabinet that sits where a radiator used to be. 1.30 – 4.35 kW heating at 50 °C, up to 7.37 kW at 70 °C.
- Four widths from 757 to 1217 mm, all 579 mm high
- Cools as well as heats: 0.81 – 3.45 kW on 7 °C water
- 170 – 630 m³/h airflow at maximum fan speed

| SKU | Model | Cooling, 7 °C water | Heating, 50 °C water | Heating, 70 °C water | Airflow | Size W × H × D |
| --- | --- | --- | --- | --- | --- | --- |
| A1567 | AFC-100CO/4A1 | 0.81 kW | 1.30 kW | 2.18 kW | 170 m³/h | 757 × 579 × 132 mm |
| A1506 | AFC-200CO/4A1 | 1.68 kW | 2.44 kW | 4.14 kW | 340 m³/h | 947 × 579 × 132 mm |
| A1568 | AFC-300CO/4A1 | 2.70 kW | 3.40 kW | 5.80 kW | 510 m³/h | 1217 × 579 × 132 mm |
| A1505 | AFC-400CO/4A1 | 3.45 kW | 4.35 kW | 7.37 kW | 630 m³/h | 1217 × 579 × 132 mm |

Capacities and airflow at maximum fan speed. DN20 water connections, DN15 drain. Supplied with a remote controller; a wall thermostat is an optional extra and control valves are not included.

#### Wall-mounted Q Series

A high-wall unit in the style of an air conditioning indoor unit, with Wi-Fi, a three-way valve and a Modbus gateway built in.
- 2.70 – 5.41 kW cooling, 3.50 – 8.16 kW heating on 60 °C water
- Two body widths: 965 and 1089 mm
- 492 – 1,020 m³/h airflow at maximum fan speed

| SKU | Model | Cooling | Heating, 60 °C water | Airflow | Size W × H × D |
| --- | --- | --- | --- | --- | --- |
| A1569 | AFC-200WM/4A(QC)-N | 2.70 kW | 3.50 kW | 492 m³/h | 965 × 325 × 230 mm |
| A1570 | AFC-300WM/4A(QC)-N | 2.91 kW | 4.07 kW | 585 m³/h | 965 × 325 × 230 mm |
| A1504 | AFC-400WM/4A(QC)-N | 3.81 kW | 5.42 kW | 825 m³/h | 965 × 325 × 230 mm |
| A1571 | AFC-500WM/4A(QC)-N | 4.51 kW | 6.77 kW | 862 m³/h | 1089 × 328 × 227 mm |
| A1503 | AFC-600WM/4A(QC)-N | 5.41 kW | 8.16 kW | 1,020 m³/h | 1089 × 328 × 227 mm |

Capacities and airflow at maximum fan speed. G 3/4″ water connections.

#### Cassette

Recessed four-way cassettes for suspended ceilings. 4.80 – 16.25 kW heating and 3.30 – 10.81 kW cooling on high speed.
- Two body sizes: 570 mm with a 650 mm panel, 835 mm with a 950 mm panel
- 250 – 290 mm deep above the ceiling
- 510 – 2,380 m³/h airflow at high fan speed

| SKU | Model | Cooling | Heating | Airflow | Body size W × D × H | Panel |
| --- | --- | --- | --- | --- | --- | --- |
| A1572 | AFC-300CA/4BA | 3.30 kW | 4.80 kW | 510 m³/h | 570 × 570 × 260 mm | 650 × 650 mm |
| A1573 | AFC-400CA/4BA | 3.90 kW | 5.80 kW | 680 m³/h | 570 × 570 × 260 mm | 650 × 650 mm |
| A1574 | AFC-500CA/4BA | 4.50 kW | 6.75 kW | 850 m³/h | 570 × 570 × 260 mm | 650 × 650 mm |
| A1575 | AFC-600CA/4BA | 5.41 kW | 8.12 kW | 1,020 m³/h | 835 × 835 × 250 mm | 950 × 950 mm |
| A1502 | AFC-800CA/4BA | 7.21 kW | 10.81 kW | 1,360 m³/h | 835 × 835 × 250 mm | 950 × 950 mm |
| A1576 | AFC-1000CA/4BA | 9.02 kW | 13.51 kW | 1,700 m³/h | 835 × 835 × 290 mm | 950 × 950 mm |
| A1577 | AFC-1200CA/4BA | 10.81 kW | 16.25 kW | 2,040 m³/h | 835 × 835 × 290 mm | 950 × 950 mm |
| A1501 | AFC-1400CA/4BA | 12.61 kW | 18.90 kW | 2,380 m³/h | 835 × 835 × 290 mm | 950 × 950 mm |

Capacities and airflow at high fan speed. Rc 3/4″ water connections.

#### Horizontal concealed M Series

Ducted units for ceiling voids and bulkheads, in left-hand or right-hand connection.
- 1.80 – 12.60 kW cooling, 2.70 – 18.90 kW heating on 60 °C water
- 240 mm high for shallow ceiling voids
- Nine widths from 694 to 1909 mm

| SKU | Model | Cooling | Heating, 60 °C water | Airflow | Size W × D × H |
| --- | --- | --- | --- | --- | --- |
| A1578 | AFC-200HCL(R)/4BA6M | 1.80 kW | 2.70 kW | 340 m³/h | 694 × 518 × 240 mm |
| A1579 | AFC-300HCL(R)/4BA6M | 2.70 kW | 4.05 kW | 510 m³/h | 894 × 518 × 240 mm |
| A1580 | AFC-400HCL(R)/4BA6M | 3.60 kW | 5.40 kW | 680 m³/h | 894 × 518 × 240 mm |
| A1581 | AFC-500HCL(R)/4BA6M | 4.50 kW | 6.75 kW | 850 m³/h | 1039 × 518 × 240 mm |
| A1582 | AFC-600HCL(R)/4BA6M | 5.40 kW | 8.10 kW | 1,020 m³/h | 1129 × 518 × 240 mm |
| A1583 | AFC-800HCL(R)/4BA6M | 7.20 kW | 10.80 kW | 1,360 m³/h | 1319 × 518 × 240 mm |
| A1584 | AFC-1000HCL(R)/4BA6M | 9.00 kW | 13.50 kW | 1,700 m³/h | 1719 × 518 × 240 mm |
| A1585 | AFC-1200HCL(R)/4BA6M | 10.80 kW | 16.20 kW | 2,040 m³/h | 1719 × 518 × 240 mm |
| A1586 | AFC-1400HCL(R)/4BA6M | 12.60 kW | 18.90 kW | 2,380 m³/h | 1909 × 518 × 240 mm |

External static pressure 30 Pa as standard, 12 Pa optional. Cooling rated at 7 / 12 °C water. Rc 3/4″ (DN20) water connections.
Sizing

### Size on the 50 °C figure

Where fan coils are served by a heat pump, size on the 50 °C heating figure unless the system design confirms a higher flow temperature.
**30 – 45 °C**
recommended heating flow temperature for fan coil units
**7 – 18 °C**
recommended cooling flow temperature for fan coil units
Documents

### Manuals and data sheets

- Slim fan coil technical manual Specifications and installation for the 130 mm slim floor-standing units. PDF · 1.6 MB
- Q Series wall-mounted technical manual Specifications, dimensions and wiring for the wall-mounted fan coils. PDF · 2.2 MB
- Four-way cassette service manual Installation, servicing and troubleshooting for the cassette fan coils. PDF · 1.9 MB
- Horizontal concealed M Series technical manual Specifications and installation for the M Series concealed ducted units. PDF · 2.4 MB
- AUX fan coil units specification Full technical data for every AUX fan coil model. XLSX · 82 KB
- Need another document? Brochures, manuals and installation guides are available from our technical team. Contact us
FAQs

### Frequently asked questions

Quick answers about using AUX fan coil units with a heat pump.

#### Fan coils and heat pumps

**Why use fan coil units with a heat pump?**
Fan coil units heat and cool from a single water circuit. They are a natural partner for a heat pump where a low flow temperature would leave radiators undersized.
**What flow temperature should fan coil units be designed for?**
The recommended heating flow temperature is 30 – 45 °C and the cooling flow temperature 7 – 18 °C. Where fan coils are served by a heat pump, size them on the 50 °C heating figure unless the system design confirms a higher flow temperature.
**Can fan coil units cool as well as heat?**
Yes. Every family cools on chilled water as well as heating. For example, the slim floor-standing units give 0.81 – 3.45 kW of cooling on 7 °C water, and the wall-mounted Q Series 2.70 – 5.41 kW.

#### Choosing a unit

**Which type of fan coil unit should I choose?**
Choose by where it goes in the room. The slim floor-standing unit is 130 mm deep and sits where a radiator used to be. The wall-mounted Q Series is a high-wall unit. Cassettes are recessed into a suspended ceiling. The concealed M Series fits ceiling voids and bulkheads, at 240 mm high.
**Are controls and valves included?**
The slim floor-standing units come with a remote controller; a wall thermostat is an optional extra and control valves are not included. The wall-mounted Q Series has Wi-Fi, a three-way valve and a Modbus gateway built in.
**Can AUX UK size fan coil units for my heat pump?**
Yes. Send us the room loads and the design flow temperature and our technical team will select the units. Contact us or call 0345 257 7387.

### Need fan coils sized for a heat pump?

Send us the room loads and design flow temperature and our technical team will select the units.

---

AUX UK (Alp Heating Ltd) · 9–10 Helix Business Park, Camberley, Surrey, GU15 2QT, United Kingdom · +44 345 257 7387 · info@auxuk.com · https://auxuk.com