## AUX VRF Systems

Variable refrigerant flow connects one outdoor unit, or a bank of modular outdoor units, to many indoor units on a single refrigerant circuit, with every room controlled on its own.
**8 – 36 HP**
ARV7 single modules, 25 – 101 kW cooling
**144 HP**
largest combined system
**−30 to 55 °C**
heating from −30 °C, cooling to 55 °C
**1,000 m**
total refrigerant piping per system
Three families

### From a large house to a hotel

The complete range is available through AUX UK.
- Mini VRF Single-phase and three-phase versions for homes, shops and small offices. 8 – 18 kW cooling See the models
- Modular Mini VRF Three-phase modules for medium-sized commercial buildings, combining into one system of up to 36 HP. 22 – 34 kW modules See the models
- ARV7 modular VRF The full DC inverter platform for offices, hotels, schools, healthcare and retail. 8 – 36 HP, to 144 HP See the models
Mini VRF

### Single outdoor units, 8 kW to 18 kW

Single-phase and three-phase versions for homes, shops and small offices. DC inverter compressors and DC fan motors for high efficiency and low noise, with a wide voltage tolerance of ±15%.
- Cooling from −15 °C to 49 °C, heating from −20 °C to 24 °C
- Settings restored automatically after a power cut
- R32 models with refrigerant recovery valve and leak alarm

#### Single phase · 220 – 240 V · R410A

| Model | Cooling | Heating | Max piping |
| --- | --- | --- | --- |
| ARV-H80/NR1B | 8.0 kW | 9.0 kW | 80 m |
| ARV-H100/NR1B | 10.0 kW | 12.0 kW | 80 m |
| ARV-H120/NR1B | 12.1 kW | 14.0 kW | 80 m |
| ARV-H140/NR1B | 14.0 kW | 16.0 kW | 100 m |
| ARV-H160/NR1A | 15.5 kW | 18.0 kW | 100 m |

#### Three phase · 380 – 415 V · DC inverter

| Model | Refrigerant | Cooling | Heating | Max piping |
| --- | --- | --- | --- | --- |
| ARV-H120/SR3DCSA | R32 | 12.1 kW | 14.0 kW | 100 m |
| ARV-H140/SR3DCSA | R32 | 14.0 kW | 16.0 kW | 100 m |
| ARV-H160/SR3DCSA | R32 | 15.5 kW | 18.0 kW | 100 m |
| ARV-H120/SR1DCS1A | R410A | 12.1 kW | 14.0 kW | 100 m |
| ARV-H140/SR1DCS1A | R410A | 14.0 kW | 16.0 kW | 100 m |
| ARV-H160/SR1DCS1A | R410A | 15.5 kW | 18.0 kW | 100 m |
| ARV-H180/SR1DCS7A | R410A | 18.0 kW | 20.0 kW | 150 m |

The main control board is cooled by refrigerant, oil return runs without switching out of heating, and settings are restored automatically after a power cut. The R32 models carry less refrigerant and a lower global warming potential than the R410A equivalents, with a built-in refrigerant recovery valve and a leak alarm for the rooms served.
Modular Mini VRF

### Three-phase modules, 22 kW to 34 kW

Three-phase modules for medium-sized commercial buildings, combining into one system of up to 36 HP.
- Largest combined system 36 HP (100.5 kW)
- Standard combinations 40 kW to 73 kW
- Total piping up to 560 m, height difference up to 50 m

#### Three phase · 380 – 415 V · ARV-HXXX/SR1DCMA

| Module | Cooling | Heating |
| --- | --- | --- |
| ARV-H224/SR1DCMA | 22.4 kW | 25.0 kW |
| ARV-H252/SR1DCMA | 25.2 kW | 27.0 kW |
| ARV-H280/SR1DCMA | 28.5 kW | 31.5 kW |
| ARV-H335/SR1DCMA | 33.5 kW | 37.5 kW |

#### System limits

**Module size**
1120 × 400 × 1540 mm
**Largest combined system**
36 HP (100.5 kW)
**Standard combinations**
40 kW to 73 kW
**Total piping**
Up to 560 m
**Height difference**
Up to 50 m
ARV7 modular VRF

### Fifteen outdoor modules, 8 HP to 36 HP

The full DC inverter platform for offices, hotels, schools, healthcare and retail. Modules combine into systems of up to 144 HP, with total piping runs of up to 1,000 m and height differences of up to 110 m between outdoor and indoor units. Three phase 380 – 415 V.
- Cooling from 25.2 kW (8 HP) to 101 kW (36 HP) per module
- Up to 61 indoor units on a single 36 HP module
- Three cabinet widths: 990, 1340 and 1850 mm

#### ARV7 outdoor modules

| Model | HP | Cooling | Heating | Max indoor units | Module size |
| --- | --- | --- | --- | --- | --- |
| ARV-H250/SR1MVB | 8 | 25.2 kW | 25.2 kW | 13 | 990 × 765 × 1635 mm |
| ARV-H280/SR1MVB | 10 | 28.0 kW | 28.0 kW | 16 | 990 × 765 × 1635 mm |
| ARV-H330/SR1MVB | 12 | 33.5 kW | 33.5 kW | 19 | 990 × 765 × 1635 mm |
| ARV-H400/SR1MVB | 14 | 40.0 kW | 40.0 kW | 23 | 1340 × 765 × 1635 mm |
| ARV-H450/SR1MVB | 16 | 45.0 kW | 45.0 kW | 26 | 1340 × 765 × 1635 mm |
| ARV-H500/SR1MVB | 18 | 50.4 kW | 50.4 kW | 30 | 1340 × 765 × 1635 mm |
| ARV-H560/SR1MVB | 20 | 56.0 kW | 56.0 kW | 33 | 1340 × 765 × 1635 mm |
| ARV-H610/SR1MVB | 22 | 61.5 kW | 61.5 kW | 36 | 1340 × 765 × 1635 mm |
| ARV-H680/SR1MVB | 24 | 68.0 kW | 75.0 kW | 40 | 1850 × 825 × 1760 mm |
| ARV-H730/SR1MVB | 26 | 73.0 kW | 81.5 kW | 42 | 1850 × 825 × 1760 mm |
| ARV-H785/SR1MVB | 28 | 78.5 kW | 87.5 kW | 46 | 1850 × 825 × 1760 mm |
| ARV-H850/SR1MVB | 30 | 85.0 kW | 95.0 kW | 49 | 1850 × 825 × 1760 mm |
| ARV-H900/SR1MVB | 32 | 90.0 kW | 100.0 kW | 53 | 1850 × 825 × 1760 mm |
| ARV-H950/SR1MVB | 34 | 95.2 kW | 106.0 kW | 57 | 1850 × 825 × 1760 mm |
| ARV-H1010/SR1MVB | 36 | 101.0 kW | 112.0 kW | 61 | 1850 × 825 × 1760 mm |

ARV7 technology

### Built for large buildings

- EVI DC inverter compressors Enhanced vapour injection scroll compressors improve part-load efficiency and heating capacity at low outdoor temperatures, with no oil balance pipe between modules.
- Variable energy-efficiency regulation Turbo, basic and high-efficiency modes change the evaporating and condensing temperatures to tune for fast response or lowest energy use.
- Back-up operation If a module or a compressor fails, the rest of the combination keeps running while a repair is arranged. Any module can act as master.
- Plant-room installation Fan static pressure of up to 70 Pa (8 – 22 HP) or 80 Pa (24 – 36 HP) allows outdoor units to be installed inside a service floor or plant room with ducted air.
- Quiet and intelligent Twelve silent levels, six for day and six for night, intelligent defrosting, and a 40 – 100% power-limiting function in seven steps.
- Straight into BMS Connects directly to the CC-02 central controller or a BACnet or Modbus building management system with no mini gateway.
Indoor units

### From 1.5 kW wall units to 56 kW high static ducts

220 – 240 V single phase unless stated. Any mix of indoor units can be combined on one system.

| Type | Model series | Capacities | Notes |
| --- | --- | --- | --- |
| Wall-mounted, C type | ARVWM-H015 to H071/NR3D(C*) | 1.5 – 7.1 kW | DC fan motor, built-in electronic expansion valve, remote controller standard |
| Compact round-way cassette | ARVCA-H15 to H56/NR1DYBB, NR3DYBB | 1.5 – 5.6 kW | Full DC fan, built-in drain pump; R32 or R410A systems |
| Round-way cassette | ARVCA-H71 to H140/NR3DQB | 7.1 – 14.0 kW | Full DC fan, built-in drain pump; R32 or R410A systems |
| One-way cassette | ARVC1-H22 to H71/NR1DS | 2.2 – 7.1 kW | Full DC fan, built-in drain pump |
| Super slim duct | ARVLD-H15 to H71/NR3DQ | 1.5 – 7.1 kW | 200 mm deep, external static pressure 10 / 30 Pa |
| Mid static duct | ARVMD-H45 to H150/NR1DM | 4.5 – 15.0 kW | External static pressure 50 / 80 Pa |
| High static duct | ARVHD-H112 to H150/4R1A | 11.2 – 15.0 kW | External static pressure 196 Pa |
| High static duct, DC | ARVHD-H220, H280/NR1DC | 22 – 28 kW | External static pressure 170 Pa, adjustable 30 – 250 Pa |
| High static duct, three phase | ARVHD-H450, H560/5R1Y | 45 – 56 kW | 380 V three phase |
| Ceiling floor | ARVCF-H28 to H140/NR1DF | 2.8 – 14.0 kW | Built-in electronic expansion valve, remote controller standard |
| Fresh air processor | ARVFA-H220, H280/NR1DC and ARVFA-H450, H560/5R1A | 22 – 56 kW | 100% fresh air; 45 and 56 kW units three phase |
| AHU kit | ARVK-0B, 00B, 01B, 02B, 03B | By AHU coil | 0 – 10 V control for third-party air handling units, wired controller included |
| Heat recovery ventilator | AHRV-200/4 to AHRV-5000/5 | 200 – 5,000 m³/h | External static pressure 75 – 240 Pa across the range |

Controls and support

### Every room on its own controller, the building on one

- Room and central control Wired controller XK-06A with timer, or an infrared remote, for each room. The CC-02 central controller runs up to 64 systems and 256 indoor units, with BACnet IP and Modbus gateways, a Wi-Fi module for app control, and billing software with smart meters for multi-let buildings.
- Ventilation AHRV heat recovery ventilators bring in fresh air while recovering heat from the extract. Refrigerant leak sensors are available for occupied rooms.
- Project support For every project we prepare the outdoor and indoor unit selection, branch pipe schedule and controls specification, and supply the AUX VRF technical catalogue with full performance data, piping limits and wiring details.
Capacities are nominal ratings from the AUX 2026 VRF catalogue: cooling at 27 °C indoor / 35 °C outdoor, heating at 20 °C indoor / 7 °C outdoor. ARV7 indoor unit capacity up to 130% of the outdoor unit as standard; larger ratios on request.
Documents

### Catalogue

- AUX VRF Catalogue Mini VRF, modular Mini VRF and ARV7 outdoor units, indoor units and controls. PDF · 13 MB
- Need another document? Brochures, manuals and installation guides are available from our technical team. Contact us
FAQs

### Frequently asked questions

Quick answers about AUX VRF systems for consultants, contractors and building owners.

#### Choosing a VRF system

**What is a VRF system?**
Variable refrigerant flow (VRF) connects one outdoor unit, or a bank of modular outdoor units, to many indoor units on a single refrigerant circuit, with every room controlled on its own.
**Which AUX VRF range do I need?**
Mini VRF, 8 to 18 kW in single and three phase, is for homes, shops and small offices. Modular Mini VRF combines 22 to 34 kW three-phase modules into one system of up to 36 HP for medium-sized commercial buildings. ARV7 modular VRF, with 8 to 36 HP modules and systems up to 144 HP, is for offices, hotels, schools, healthcare and retail.
**How many indoor units can one VRF system have?**
Up to 61 indoor units on a single 36 HP ARV7 module. Indoor unit capacity can be up to 130% of the outdoor unit as standard, with larger ratios on request, and any mix of indoor units – from 1.5 kW wall units to 56 kW high static ducts – can be combined on one system.

#### Design and control

**What are the piping limits of AUX VRF?**
ARV7 allows up to 1,000 m of total refrigerant piping per system and height differences of up to 110 m between outdoor and indoor units. Modular Mini VRF allows up to 560 m of total piping and a height difference of up to 50 m.
**Can AUX VRF connect to a building management system?**
Yes. ARV7 connects directly to the CC-02 central controller, or to a BACnet or Modbus building management system, with no mini gateway. The CC-02 runs up to 64 systems and 256 indoor units, with BACnet IP and Modbus gateways, a Wi-Fi module for app control and billing software for multi-let buildings.
**What does AUX UK prepare for a VRF project?**
For every project we prepare the outdoor and indoor unit selection, the branch pipe schedule and the controls specification, and supply the AUX VRF technical catalogue with full performance data, piping limits and wiring details. Send us your project to start.

### Send us your project

We prepare the outdoor and indoor unit selection, branch pipe schedule and controls specification for every VRF project.

---

AUX UK (Alp Heating Ltd) · 9–10 Helix Business Park, Camberley, Surrey, GU15 2QT, United Kingdom · +44 345 257 7387 · info@auxuk.com · https://auxuk.com